Rinnai INFINITY® EFi250 Internal
- Features
- Suitable for
- Technical
- Accessories
- CAD/BIM
Colour
Gunmetal Grey
Input
211 MJ/h or 58.6 kW
Output
55.6 kW
Efficiency
95%
Energy Star Rating
REU number: | REU-KM3237FFUD-ZK |
Factory preset temperature: | 55 °C |
Rinnai product code: | INFEF250FFN/INFEF250FFL |
Capacity | Hot water capacity: 1.5-37 litres per minute Nominal water capacity: 32 litres per minute at a 25 ° rise (1920 L/h) |
Connections | Hot water outlet: R¾ (20 mm) Cold water inlet: R¾ (20 mm) Gas supply: R¾ (20 mm) Condensate: R½ (15 mm) |
Exhaust system | Forced flue (balanced flued, room sealed fan assisted appliance). Flue dimensions; inner - 80 mm, outer 125 mm |
Frost protection | Fitted as standard. Frost protection operates automatically, as long as the appliance is connected to the electrical power supply, by activating when the temperature inside the unit drops below 3.5 °C, and turns off once the temperature inside the unit reaches 7 °C. |
Ignition system | Direct electronic ignition |
Injector size | NG: 1.15, 1.9, 1.8* LPG: 0.75, 1.15, 1.1* * only one point |
Line pressure (min.) | NG: 1.13 kPa, LPG: 2.75 kPa |
Line pressure (max.) | 3.5 kPa (maximum standing pressure under abnormal intermittent conditions is 5.0 kPa). In the case of commercial metering (i.e. 35-37 kPa coming in), there may be a requirement to regulate the incoming line pressure down. |
Power consumption | Normal: LPG - 92 W, NG - 72 W Automatic frost protection: 218 W Standby: 2.4 W |
Noise level | 50 dB(A) |
NOx af | < 60 ppm |
Safety devices | Flame failure, boil-dry protection, overheat protection (OHS), fusible link, pressure relief valve, combustion fan rpm check |
Water supply | Nominal operating pressure: 240-1000 kPa Minimum water flow: 1.5 litres per minute |
Weight | 32 kg |
Market release | July 2011 |
Compliance | ES: Supplier Declaration of Compliance • Declaration Number: 1008720096 • Certificate Number: 7083 |
RINNAI EF250 INTERNAL
$3,499.00 Regular Price
$3,088.00Sale Price