- Accessories
Colour
White
Efficiency
80%
Energy Star Rating
Factory preset temp. | 55 °C |
Model code and REU numbers |
|
Hot water capacity |
|
Input and output | A16: Input: 16.3-124 MJ/h, output 27.4 kW |
A20: Input: 19.9-156 MJ/h, output 33.9 kW | |
A24: Input: 16.3-184 MJ/h, output 41.4 kW | |
A26: Input: 16.3-199 MJ/h, output 44.2 kW | |
Exhaust system | Forced flue |
Frost protection | Fitted as standard. Frost protection operates automatically, as long as the appliance is connected to the electrical power supply, by activating when the temperature inside the unit drops below 3.5 °C, and turns off once the temperature inside the unit reaches 7 °C. |
Ignition system | Direct electronic ignition |
Injector sizes | A16: NG: 0.9, 1.50, LPG: 0.71, 1.09 |
A20-A26: NG: 1.08, 1.80, LPG: 0.73, 1.12 | |
Line pressure (min.) | NG: 1.13 kPa, LPG 2.75 kPa |
Line pressure (max.) | 3.5 kPa (maximum standing pressure under abnormal intermittent conditions is 5.0 kPa). In the case of commercial metering, (i.e. 35-37 kPa coming in), there may be a requirement to regulate the incoming pressure down). |
Power consumption | Normal: 47 W (A16), 58 W (A20), 56 W (A24), 66 W (A26) Standby: 2 W Automatic Frost Protection: 68 W |
Pressure relief | Valve opens at 2060 kPa Valve closes at 1479 kPa |
Noise level | 50 dB(A) |
NOx af | 35 ppm |
Safety devices | Flame failure, boil-dry protection, overheat protection, fusible link, pressure relief valve and combustion fan rpm check |
Water supply | Nominal operating pressure: - 120-1000 kPa (A16)- 160-1000 kPa (A20) - 200-1000 kPa (A24 & A26)
Activation flow rate: 1.5 litres per minute |
Weights | A16 = 13 kg, A20 = 14 kg, A24 and A26 = 15 kg |
Compliance | ES: Supplier Declaration of Compliance Declaration numbers: • A16 - 1825920179 • A20 - 1825820179 • A26 - 1825620179 |
Market release | 2018 |
RINNAI INFINITY A20
$1,799.00 Regular Price
$1,595.00Sale Price